ATV &16-ChannelTalon Triplex Color Multiplexers Instructions d'exploitation Page 34

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 56
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 33
26
On / Off: This turns the motion detection option for the selected mode either ON or
OFF.
Update / Master: When set to the Update option, the multiplexer compares the current
field with the previous field. When set to the Master option, the multiplexer compares a
master image to continuous video.
Normal / Vector: When set to Normal, the multiplexer detects all motion. When set to
Vector, the multiplexer detects motion based on user definitions.
Sensitivity: The Sensitivity option determines the luminance change that must occur in
the target area before the multiplexer reads the change as motion. The lowest
sensitivity number is 01. The highest sensitivity number is 16.
Trigger Size (H) and (V): The Trigger Size sets the minimum number of targets in a
vertical row that must change before the multiplexer reads the change as motion. The
range is 01 to 16.
Delay Time: The Delay Time is used to make adjustments for scenes that have sudden
changes such as lights and shadows created by headlights or nearby traffic. The delay
can be set from 0 to 5 seconds.
Hold Time: The Hold Time can be set from 1 to 99 seconds.
Grid Setup: The Grid Setup option brings up the Motion Detection Sensor Setup
screen shown below on the left.